Altigen MAXCS 7.0 Update 1 MultiVOIP Configuration User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
MAXCS 7.0 Update 1MultiVoIP Configuration Guide Page 14 of 27
To configure SIP-Tie Trunks, follow these steps:
1. Open the MultiVoIP configuration tool.
2. Select Configuration > Voice/Fax and configure these parameters:
Set Select Channel to Channel 3
Set DTMF to Out of Band Fixed Duration
Set Out Of Band Mode to SIP Info
Set Coder to Manual
Set Selected Coder to [email protected]ps
Set Auto Call/OffHook Alert to Auto Call
Check Generate Local Dial Tone.
Set Phone Number to 150 (This means when the gateway sends a call to MaxCS, it will try to
ring extension 150. If extension 150 does not exist, the call will be sent to the MaxCS Auto
Attendant system.)
3. Select Configuration > Interface and configure the following parameters:
Set Select Channel to Channel 3
Set Interface Type to FXO