By default, the system grants 60 conference members in a maximum of 40 bridges.
You can change the number to as many as 120 members in a maximum of 40 bridges, and you can activate
other HMCP resources.
1. In MAXCS Administrator, open the Boards panel and double-click HMCP.
2. Click Board Configuration.
3. Adjust the assigned number by entering a different number (up to the number your system is licensed
for and not to exceed the maximum limit for each HMCP board) in the Assigned to this board fields
and clicking Apply.